ReliOn Thermometer K 144 732 000 User Guide

General Care  
LIFETIME LIMITED WARRANTY  
FAST 10-Second  
Taking an Oral Temperature  
Approximate measurement time:  
15 seconds  
1. The thermometer should only be used under the supervision of an adult.  
2. Do not walk, run or talk during temperature taking.  
3. Clean the thermometer before and after each use.  
4. Store the unit in the protective case when not in use.  
5. Do not bite the thermometer tip.  
This ReliOn® Digital Thermometer is guaranteed to be free from manufacturing defects for the life of the original registered purchaser under  
normal use. This limited warranty does not apply to use in any clinical or commercial applications. If the unit fails to operate during the lifetime of  
the original registered purchaser, return it postage prepaid to: Repair Department, 1931 Norman Drive, Waukegan, IL 60085. If ReliOn® determines  
that the unit failed to operate due to a manufacturing defect, the unit will be repaired or replaced at the option of ReliOn®. Repair or replacement  
of the unit is the sole remedy under this limited warranty. This warranty gives you specific legal rights, which vary from state to state. As a  
condition of this warranty, the enclosed warranty registration card must be completed and sent to us within 10 days of the purchase date.  
Digital Thermometer  
Thank you for purchasing a ReliOn® Digital Thermometer. Please read the following  
instructions to achieve the most accurate temperatures and safe operation. With  
proper care and use, your thermometer will provide you with years of reliable  
readings.  
HEAT  
POCKET  
1. Using the diagram on the right, place  
the thermometer tip tip under the  
tongue as near as possible to the heat  
pocket. The diagram also shows the  
temperature variables by not placing the  
tip in the heat pocket area.  
HEAT  
POCKET  
98.8oF  
98.8oF  
6. Do not store the unit where it will be exposed to direct sunlight, dust or humidity.  
Avoid extreme temperatures.  
7. Dropping or subjecting your thermometer to strong shocks should be avoided.  
8. Do not attempt to disassemble the unit, except to replace the battery.  
9. If ERR displays and measurement is not attainable, the unit must be replaced.  
98.4oF  
98.4oF  
This Limited Warranty constitutes ReliOn®’s only responsibility and obligation to repair and/or replace materials or components. We make no other  
express or implied warranties, arising by operation of law or otherwise, or any warranty of merchantability or fitness for a particular use or purpose  
whether or not the use or purpose has been disclosed to ReliOn® in specifications, drawings or otherwise, and whether or not ReliOn®’s products  
are specifically designed and/or manufactured by ReliOn® for the buyer’s use or purposes, except for the limited warranty stated above. ReliOn®  
will not be responsible for any indirect, incidental, special, consequential, or punitive damages or other loss, including, but not limited to, damage  
to or loss of other property or equipment and personal injuries, whether to purchaser or others. ReliOn® shall in no event be liable to the  
purchaser for any amount in excess of the cost of repair and/or replacement of the unit.  
What is a “NormalTemperature?  
Although the generally accepted “normal” temperature reading is 98.6oF, tempera-  
ture readings can vary from 97oF to 99oF and still may be considered “normal”.  
Variations in temperature can be attributed to activities such as exercise, smoking,  
eating and drinking. Even time of day may influence your temperature. For exam-  
ple, your temperature is lower in the morning than in the afternoon. Other variations  
may be due to the location of the temperature reading. While the oral temperature  
follows the guidelines previously described, a rectal temperature is generally 1.0oF  
higher. Conversely, an axillary (under the arm) temperature will be 1.0oF lower.  
98.1oF  
97.7oF  
97.9oF  
97.9oF  
NOTE: Drinking hot or cold fluids, exercis-  
ing, smoking or performing other activities  
may raise or lower your temperature.  
Therefore, it is important to relax for  
approximately 5 minutes with your mouth  
closed prior to taking a reading  
NOTE: Performance of the device may be degraded if: operated outside of  
stated temperature and humidity range; stored outside of stated temperature  
and humidity range; thermometer undergoes mechanical shock (drop); patient  
temperature is below ambient temperature.  
Changing the Battery  
2. The current temperature is shown and the oF will continue to flash during the  
reading.  
The battery in your digital thermometer needs to be replaced when the “  
” sym-  
Features of your ReliOn® Digital Thermometer  
bol appears in the lower right of the display. Replace the battery with a 1.55V, AG3  
alkaline or SR41 silver oxide type or equivalent.  
To replace the battery,  
3. When the peak temperature has been reached, the oF will stop flashing and the  
thermometer will sound four sets of five quick beeps.  
4. To turn the unit off, press the ON/OFF button. The unit will automatically shut off  
after approximately nine minutes.  
PROBE COVER ORDER FORM  
CUT OUT AND MAIL TO:  
BATTERY COVER  
DIGITAL DISPLAY WINDOW  
WARRANTY REGISTRATION DEPARTMENT  
1. Slide the battery cap away from the unit.  
CUT OUT AND MAIL TO:  
2. Using a non-metal pointed tool, carefully remove the  
battery and insert the new battery with the negative (–)  
side facing the back side of the unit.  
3. Carefully slide the battery cap back into place, making  
sure that the cap fits snugly to protect the battery com-  
partment from moisture.  
1931 NORMAN DRIVE  
WAUKEGAN, IL 60085  
MABIS HEALTHCARE INC.  
1931 NORMAN DRIVE  
WAUKEGAN, IL 60085  
NOTE: The mouth must remain closed during the measurement for the most accu-  
rate reading. Opening the mouth could result in an extended measurement time  
and may affect the reading.  
THERMOMETER WARRANTY REGISTRATION  
(MUST BE COMPLETED WITHIN 10 DAYS OF PURCHASE)  
THERMOMETER TIP  
Please send  
packages of disposable probe  
ON/OFF BUTTON  
Taking an Axillary Temperature (under the arm)  
NOTE: Please properly dispose the battery away from small children and heat.  
covers #15-618-000 (100 probes per package). Enclosed  
is $5.00 per package plus $3.00 for shipping and handling  
for each order.  
NAME:  
Approximate measurement time: 20 seconds  
Specifications  
DISPLAY:  
ADDRESS:  
1. Wipe the underarm with a dry towel.  
2. Place the thermometer tip under the arm so the tip is touching the skin with the  
thermometer perpendicular to the body.  
3. Position the arm across the chest so the thermometer tip tip is well covered by  
the arm. This also insures the thermometer tip is not affected by the room’s air.  
4. When the peak temperature has been reached, the oF will stop flashing and the  
thermometer will sound four sets of five quick beeps.  
Cleaning Instructions  
Liquid Crystal Display  
Before and after each use, clean the thermometer with a soft cloth and 70%  
isopropyl alcohol diluted with water, or wash with COLD soapy water. An intact unit  
can be submersed in water or alcohol. However, do not soak for an extended period  
of time.  
1. The unit must never be sterilized by boiling, gas or steam autoclaves.  
2. The use of any other solution or cleaning method beyond the above mentioned  
may result in reliability problems with the thermometer and void your warranty.  
PAYMENT METHOD (do not send cash):  
Please ship to:  
Check  
Money Order  
DISPLAY RESOLUTION:  
MEASUREMENT RANGE:  
ACCURACY:  
4 Digits (1/10TH of a degree increments)  
CITY:  
STATE:  
STATE:  
ZIP:  
ZIP:  
90.0˚F to 111.9˚F  
PURCHASED FROM:  
CITY:  
0.2˚F  
AVERAGE MEASUREMENT TIME:  
TONE:  
Oral 15.2 seconds. Rectal 10.2 seconds. Axillary 20.8 seconds  
NAME:  
5. To turn the unit off, press the ON/OFF button. The unit will automatically shut off  
after approximately nine minutes.  
Thermometer beeps when activated and deactivated.  
A series of beeps signal when peak temperature is reached.  
ADDRESS:  
CITY:  
NOTE: Axillary temperatures are generally 1.0oF lower than oral readings.  
DATE PURCHASED:  
How to Take Your Temperature  
MEMORY:  
Displays last measured temperature  
One, 1.55V, AG3 alkaline  
Approximately 4,000 measurements  
After approximately 9 minutes  
50.0˚F to 113.0˚F  
1. Clean and disinfect the thermometer according the instructions provided.  
2. Apply a disposable thermometer tip cover to the clean, dry thermometer.  
3. Determine whether the measurement site will be oral, rectal or underarm.  
NOTE: Measurement time may vary based on the selected site.  
4. Press the ON/OFF button (the unit will beep) to activate the thermometer.  
MODEL PURCHASED:  
STATE:  
ZIP:  
BATTERY:  
K 144-732-000  
Taking a Rectal Temperature  
BATTERY LIFE:  
PHONE:  
(
)
Approximate measurement time: 10 seconds  
USER INFORMATION (OPTIONAL)  
AUTOMATIC SHUT-OFF:  
AMBIENT OPERATING TEMPERATURE:  
DIMENSIONS:  
K MALE K FEMALE  
AGE:  
NOTE: Rectal temperatures are an appropriate and reliable method for infants and  
small children. Otherwise, this method should only be used when it is impossible or  
impractical to take an oral or axillary temperature.  
1. After applying the disposable thermometer tip cover, apply a water-soluble lubri-  
cant to the tip.  
2. Gently insert the thermometer tip a MAXIMUM of 1/2” into the rectum.  
3. When the peak temperature has been reached, the oF will stop flashing and the  
thermometer will sound four sets of five quick beeps.  
NOTE: This order form is for shipments within the United States  
and Canada.  
AGE OF YOUNGEST FAMILY MEMBER  
K UNDER 6 MONTHS  
K 6 MONTHS - 1 YEAR  
K 1 - 3 YEARS  
This is the LCD display test, which insures all parts of the dis-  
play are functioning properly. Continue to hold the button down  
and in approximately 2 seconds the display will show the last  
recorded temperature as follows.  
5-3/16” x 11/16” x 3/8”  
WEIGHT:  
0.34 ounces  
Specifications are subject to change without notice.  
K 3 - 5 YEARS  
K OLDER  
This display shows the last temperature reading. Within  
approximately 2 seconds of releasing the button or if no  
reading is stored in memory, the display will read as follows.  
Manufactured for:  
4. To turn the unit off, press the ON/OFF button. The unit will automatically power  
down after approximately ten minutes.  
MABIS Healthcare Inc.  
1931 Norman Drive  
Waukegan, IL 60085 USA  
NOTE: Rectal temperatures are generally 1.0oF higher than oral readings.  
This display denotes normal operation.  
“Err” denotes a malfunction.  
Using Disposable Thermometer Tip Covers  
It is recommended to use the enclosed disposable thermometer tip covers to pre-  
vent cross contamination. ReliOn® thermometer tip covers can be purchased from  
your local Wal-Mart retailer or with the order form provided.  
Meets ASTM Standard E1112  
Made in China  
The Lo with the flashing oF indicates the thermometer is ready  
to take a temperature reading.  
#144-ACT2030 05/04  
®
ReliOn® is a trademark under license by MABIS Healthcare Inc.  
 
©2004 ReliOn  

Rosen Entertainment Systems GPS Receiver DS TY0710 User Guide
Rotel DVD Player RDV 985 User Guide
RuggedCom Network Router WIN7000 User Guide
Russound Home Theater Server SMS3 User Guide
Salton Toaster FAC200T User Guide
Samsung All in One Printer SCX 4623F User Guide
Samsung Washer Dryer DC68 02040A 01 User Guide
Sangean Electronics Portable Radio ATS 505P User Guide
Sears Stepper Machine 83129723 User Guide
Senco Nail Gun 700XL User Guide